RENSCO MWD Engineer
RENSCO MWD Cabins
MWD Tool String
MWD Tool Kit Box
MWD Tool Kit Box
MWD Manager (Art Poffenroth)

MEASUREMENT WHILE DRILLING (MWD)

 

 

RENSCO MWD TOOL CAPABILITIES

 

·         Various drill collar sizes, 3 1/2” to 9 1/2” or larger

·         Wireline retrievable

·         Components of MWD down hole system (i.e. pulser module, gamma module, directional module, battery module,). All components of the MWD down hole system are intermodular to adjust for optimal sensor to bit measurements

·         Down hole systems rated for 150°C/302°F or high temperature rated to 175°C/347°F

·         Primary and secondary backup down hole battery supply that operates 300 circulating hours/battery pack

·         Maximum pressure rating = 20,000 psi

·         LCM tolerance – 50 to 60 ppb (premixed)

·         Flow ranges listed in attached brochure

·         Rotary pulser option for high solids and LCM

·         EM telemetry system option for underbalanced, air drill and continuous data updates not dependant on mud flow medium

·         Real time and recorded full MWD survey data measurements, toolface, temperature, gamma and depth tracking

MWD REPAIR AND MAINTENANCE FACILITY

  • MWD Repair Lab full MWD diagnostic capabilities, Directional Electonics, Batteries, Gamma Ray Sensors, and Pulser mechanical maintenance

 

  • Oven for High Temperature Downhole tool qualification

 

  • Electronic board level repairs

 

  • Directional Sensor Roll Test Qualification

 

  • Gamma Ray Sensor Testing Equipment

MWD Repair Lab

Inside RENSCO MWD Cabin

MWD Directional Electronics Service Area

RENSCO MWD Cabin